Circuit Breaker 10 amp Information
- Rated Current: 10 amp
- Rated Voltage: 230/400V AC, 50Hz
- Number of poles: 1 pole
- DIN rail mounted and module width of only 18 mm (per pole)
- 6 kA short circuit interrupting capacity
- Thermal-magnetic overcurrent protection, three levels of short circuit protection, categorized by C curve
Technical Data
Model | ATO-NB8-631PC10 | |
Electrical Parameters | Height | 86 mm |
Width | 18 mm per pole | |
Mounting | DIN Rail | |
Rated Current (In) | 10A | |
Number of poles | 1P | |
Rated Voltage (Ue) | 230/400V | |
Rated Insulation Voltage (Ui) | 500V | |
Dielectric Test Voltage | 2000V | |
Reted Frequency | 50Hz | |
Short Circuit Interrupting Capacity | 6KA | |
Trip Characteristic | C Curve (5-10In) | |
Rated Short-Circuit Breaking Capacity | 6000A | |
Operating Short-Circuit Breaking Capacity | 6000A | |
Mechanical Parameters | Electrical Life | 10000 times |
Mechanical Life | 20000 times | |
Flame Retardant Grade | V0 | |
Protection Degree | Direct installation: IP20B Installed in the distribution box: IP40B |
|
Calibration Temperature | 30℃ | |
Operating Temperature | -35℃~+70℃ | |
Storage Temperature | -35℃~+85℃ | |
Tightening Torque | 2 N.m | |
Max. Tolerable Torque | 2.5 N.m | |
Terminal Size Acceptability–Min/Max | 1 mm2 / 25mm2 | |
Wire Insertion Depth | 13mm |
Circuit Breaker 16 amp Information
- Rated Current: 16 amp
- Rated Voltage: 230/400V AC, 50Hz
- Number of poles: 1 pole
- DIN rail mounted and module width of only 18 mm (per pole)
- 6 kA short circuit interrupting capacity
- Thermal-magnetic overcurrent protection, C curve of short circuit protection
Technical Data
Model | ATO-NB8-631PC16 | |
Electrical Parameters | Height | 86 mm |
Width | 18 mm per pole | |
Mounting | DIN Rail | |
Rated Current (In) | 16A | |
Number of poles | 1P | |
Rated Voltage (Ue) | 230/400V | |
Rated Insulation Voltage (Ui) | 500V | |
Dielectric Test Voltage | 2000V | |
Reted Frequency | 50Hz | |
Short Circuit Interrupting Capacity | 6KA | |
Trip Characteristic | C Curve (5-10In) | |
Rated Short-Circuit Breaking Capacity | 6000A | |
Operating Short-Circuit Breaking Capacity | 6000A | |
Mechanical Parameters | Electrical Life | 10000 times |
Mechanical Life | 20000 times | |
Flame Retardant Grade | V0 | |
Protection Degree | Direct installation: IP20B Installed in the distribution box: IP40B |
|
Calibration Temperature | 30℃ | |
Operating Temperature | -35℃~+70℃ | |
Storage Temperature | -35℃~+85℃ | |
Tightening Torque | 2 N.m | |
Max. Tolerable Torque | 2.5 N.m | |
Terminal Size Acceptability–Min/Max | 1 mm2 / 25mm2 | |
Wire Insertion Depth | 13mm |
Reviews